{"id":7214,"date":"2024-02-08T21:06:19","date_gmt":"2024-02-09T02:06:19","guid":{"rendered":"https:\/\/staging.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/"},"modified":"2024-02-09T02:08:05","modified_gmt":"2024-02-09T02:08:05","slug":"corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier","status":"publish","type":"post","link":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/","title":{"rendered":"Corroded wire rope leads to crane failure on bulk carrier"},"content":{"rendered":"<p>Undetected corrosion and wear led to an equipment failure on a cargo ship while offloading cargo in Houston, the National Transportation Safety Board (NTSB) said.<\/p>\n<p>On July 23, 2022, the cargo ship Thorco Basilisk was offloading a wind turbine component at the Greensport Terminal on the Houston Ship Channel when the hoisting wire rope on one of the ship\u2019s cargo cranes failed, causing the component to drop onto the vessel\u2019s cargo hold tween deck.<\/p>\n<p>No injuries were reported. Damages to the ship and cargo were estimated between $3-5 million.<\/p>\n<p>An examination of the hoisting wire rope showed significant external corrosion and wear; however, the visible signs of external corrosion could not be fully seen until the grease on the rope was removed. While annual surveys were performed on the wire ropes, the surveys primarily involved visual inspections to look for wear and would not have identified the underlying corrosion below the grease.<\/p>\n<p>While the hoisting wire rope had been in use for 9 years, still within the standard 10-year period of use, a post-casualty examination found \u201cthe wire rope was near the end of its service life and probably should have been discarded.\u201d The operating company has since updated their planned maintenance system to require crane wire rope replacement every 5 years.<\/p>\n<p>\u201cSaltwater and humid ocean air cause corrosion of metals, presenting challenges for the maintenance of high-strength steel wire ropes on vessels,\u201d the report said. \u201cA deteriorated wire rope directly affects a crane\u2019s ability to safely and reliably handle loads up to its rated capacity (safe working load). Therefore, diligent inspection, maintenance, and management of wire ropes are essential. Working wires should be changed at recommended intervals, or more frequently, depending on operating conditions and use.\u201d<\/p>\n<p>&nbsp;<\/p>\n<p>Image &#8211; <em>The Thorco Basilisk\u2019s parted hoisting wire rope (crane side of fracture) was evaluated by a consulting company. Courtesy of: Engineering Systems Inc.<\/em><\/p>\n<p>&nbsp;<\/p>\n<p>For more information:<\/p>\n<p>National Transportation Safety Board<\/p>\n<p><a href=\"https:\/\/www.ntsb.gov\">https:\/\/www.ntsb.gov<\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Undetected corrosion and wear led to an equipment failure on a cargo ship while offloading cargo in Houston, according to the National Transportation Safety Board.<\/p>\n","protected":false},"author":63245,"featured_media":7217,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[586,587,588,499,589,504,590,480,474,475,591,584,592],"tags":[],"class_list":["post-7214","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-corrosion","category-corrosion-fatigue","category-environmental-impacts","category-failure-analysis","category-friction-and-wear","category-marine-applications","category-maritime-ships","category-materials-properties-and-performance","category-news","category-news-articles","category-seawater-and-marine-environments","category-stainless-steels","category-stress-corrosion-cracking"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Corroded wire rope leads to crane failure on bulk carrier - Failure Analysis Society<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Corroded wire rope leads to crane failure on bulk carrier - Failure Analysis Society\" \/>\n<meta property=\"og:description\" content=\"Undetected corrosion and wear led to an equipment failure on a cargo ship while offloading cargo in Houston, according to the National Transportation Safety Board.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/\" \/>\n<meta property=\"og:site_name\" content=\"Failure Analysis Society\" \/>\n<meta property=\"article:published_time\" content=\"2024-02-09T02:06:19+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-09T02:08:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.asminternational.org\/app\/uploads\/sites\/42\/2024\/02\/FAS__021524__NTSB__250-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"250\" \/>\n\t<meta property=\"og:image:height\" content=\"108\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Debbie Sniderman\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Debbie Sniderman\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\\\/\"},\"author\":{\"name\":\"Debbie Sniderman\",\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/#\\\/schema\\\/person\\\/135b2d8ac98a363d0bd9ec033a2904ad\"},\"headline\":\"Corroded wire rope leads to crane failure on bulk carrier\",\"datePublished\":\"2024-02-09T02:06:19+00:00\",\"dateModified\":\"2024-02-09T02:08:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\\\/\"},\"wordCount\":335,\"publisher\":{\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cdn-prd-main.asm-media.cloud\\\/uploads\\\/sites\\\/42\\\/2024\\\/02\\\/FAS__021524__NTSB__250-1.jpg\",\"articleSection\":[\"Corrosion\",\"Corrosion fatigue\",\"Environmental Impacts\",\"Failure Analysis\",\"Friction and Wear\",\"Marine Applications\",\"Maritime - ships\",\"Materials Properties and Performance\",\"news\",\"News Articles\",\"Seawater and marine environments\",\"Stainless Steels\",\"Stress-corrosion cracking\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\\\/\",\"url\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\\\/\",\"name\":\"Corroded wire rope leads to crane failure on bulk carrier - Failure Analysis Society\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cdn-prd-main.asm-media.cloud\\\/uploads\\\/sites\\\/42\\\/2024\\\/02\\\/FAS__021524__NTSB__250-1.jpg\",\"datePublished\":\"2024-02-09T02:06:19+00:00\",\"dateModified\":\"2024-02-09T02:08:05+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\\\/#primaryimage\",\"url\":\"https:\\\/\\\/cdn-prd-main.asm-media.cloud\\\/uploads\\\/sites\\\/42\\\/2024\\\/02\\\/FAS__021524__NTSB__250-1.jpg\",\"contentUrl\":\"https:\\\/\\\/cdn-prd-main.asm-media.cloud\\\/uploads\\\/sites\\\/42\\\/2024\\\/02\\\/FAS__021524__NTSB__250-1.jpg\",\"width\":250,\"height\":108},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Corroded wire rope leads to crane failure on bulk carrier\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/#website\",\"url\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/\",\"name\":\"Failure Analysis Society\",\"description\":\"Failure Analysis Society ASM International\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/#organization\",\"name\":\"Failure Analysis Society\",\"url\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/cdn-prd-main.asm-media.cloud\\\/uploads\\\/sites\\\/42\\\/2022\\\/10\\\/layout_set_logo.png\",\"contentUrl\":\"https:\\\/\\\/cdn-prd-main.asm-media.cloud\\\/uploads\\\/sites\\\/42\\\/2022\\\/10\\\/layout_set_logo.png\",\"width\":241,\"height\":94,\"caption\":\"Failure Analysis Society\"},\"image\":{\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/#\\\/schema\\\/person\\\/135b2d8ac98a363d0bd9ec033a2904ad\",\"name\":\"Debbie Sniderman\",\"url\":\"https:\\\/\\\/www.asminternational.org\\\/fas\\\/author\\\/dsniderman\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Corroded wire rope leads to crane failure on bulk carrier - Failure Analysis Society","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/","og_locale":"en_US","og_type":"article","og_title":"Corroded wire rope leads to crane failure on bulk carrier - Failure Analysis Society","og_description":"Undetected corrosion and wear led to an equipment failure on a cargo ship while offloading cargo in Houston, according to the National Transportation Safety Board.","og_url":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/","og_site_name":"Failure Analysis Society","article_published_time":"2024-02-09T02:06:19+00:00","article_modified_time":"2024-02-09T02:08:05+00:00","og_image":[{"width":250,"height":108,"url":"https:\/\/www.asminternational.org\/app\/uploads\/sites\/42\/2024\/02\/FAS__021524__NTSB__250-1.jpg","type":"image\/jpeg"}],"author":"Debbie Sniderman","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Debbie Sniderman","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/#article","isPartOf":{"@id":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/"},"author":{"name":"Debbie Sniderman","@id":"https:\/\/www.asminternational.org\/fas\/#\/schema\/person\/135b2d8ac98a363d0bd9ec033a2904ad"},"headline":"Corroded wire rope leads to crane failure on bulk carrier","datePublished":"2024-02-09T02:06:19+00:00","dateModified":"2024-02-09T02:08:05+00:00","mainEntityOfPage":{"@id":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/"},"wordCount":335,"publisher":{"@id":"https:\/\/www.asminternational.org\/fas\/#organization"},"image":{"@id":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/#primaryimage"},"thumbnailUrl":"https:\/\/cdn-prd-main.asm-media.cloud\/uploads\/sites\/42\/2024\/02\/FAS__021524__NTSB__250-1.jpg","articleSection":["Corrosion","Corrosion fatigue","Environmental Impacts","Failure Analysis","Friction and Wear","Marine Applications","Maritime - ships","Materials Properties and Performance","news","News Articles","Seawater and marine environments","Stainless Steels","Stress-corrosion cracking"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/","url":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/","name":"Corroded wire rope leads to crane failure on bulk carrier - Failure Analysis Society","isPartOf":{"@id":"https:\/\/www.asminternational.org\/fas\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/#primaryimage"},"image":{"@id":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/#primaryimage"},"thumbnailUrl":"https:\/\/cdn-prd-main.asm-media.cloud\/uploads\/sites\/42\/2024\/02\/FAS__021524__NTSB__250-1.jpg","datePublished":"2024-02-09T02:06:19+00:00","dateModified":"2024-02-09T02:08:05+00:00","breadcrumb":{"@id":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/#primaryimage","url":"https:\/\/cdn-prd-main.asm-media.cloud\/uploads\/sites\/42\/2024\/02\/FAS__021524__NTSB__250-1.jpg","contentUrl":"https:\/\/cdn-prd-main.asm-media.cloud\/uploads\/sites\/42\/2024\/02\/FAS__021524__NTSB__250-1.jpg","width":250,"height":108},{"@type":"BreadcrumbList","@id":"https:\/\/www.asminternational.org\/fas\/corroded-wire-rope-leads-to-crane-failure-on-bulk-carrier\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.asminternational.org\/fas\/"},{"@type":"ListItem","position":2,"name":"Corroded wire rope leads to crane failure on bulk carrier"}]},{"@type":"WebSite","@id":"https:\/\/www.asminternational.org\/fas\/#website","url":"https:\/\/www.asminternational.org\/fas\/","name":"Failure Analysis Society","description":"Failure Analysis Society ASM International","publisher":{"@id":"https:\/\/www.asminternational.org\/fas\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.asminternational.org\/fas\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.asminternational.org\/fas\/#organization","name":"Failure Analysis Society","url":"https:\/\/www.asminternational.org\/fas\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.asminternational.org\/fas\/#\/schema\/logo\/image\/","url":"https:\/\/cdn-prd-main.asm-media.cloud\/uploads\/sites\/42\/2022\/10\/layout_set_logo.png","contentUrl":"https:\/\/cdn-prd-main.asm-media.cloud\/uploads\/sites\/42\/2022\/10\/layout_set_logo.png","width":241,"height":94,"caption":"Failure Analysis Society"},"image":{"@id":"https:\/\/www.asminternational.org\/fas\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.asminternational.org\/fas\/#\/schema\/person\/135b2d8ac98a363d0bd9ec033a2904ad","name":"Debbie Sniderman","url":"https:\/\/www.asminternational.org\/fas\/author\/dsniderman\/"}]}},"acf":[],"_links":{"self":[{"href":"https:\/\/www.asminternational.org\/fas\/wp-json\/wp\/v2\/posts\/7214","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.asminternational.org\/fas\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.asminternational.org\/fas\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.asminternational.org\/fas\/wp-json\/wp\/v2\/users\/63245"}],"replies":[{"embeddable":true,"href":"https:\/\/www.asminternational.org\/fas\/wp-json\/wp\/v2\/comments?post=7214"}],"version-history":[{"count":0,"href":"https:\/\/www.asminternational.org\/fas\/wp-json\/wp\/v2\/posts\/7214\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.asminternational.org\/fas\/wp-json\/wp\/v2\/media\/7217"}],"wp:attachment":[{"href":"https:\/\/www.asminternational.org\/fas\/wp-json\/wp\/v2\/media?parent=7214"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.asminternational.org\/fas\/wp-json\/wp\/v2\/categories?post=7214"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.asminternational.org\/fas\/wp-json\/wp\/v2\/tags?post=7214"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}